Dixon Systems NM-250 MKII
Logic and Control
All signal switching in the NM-250 MKII is accomplished using miniature 24 VDC
relays. Each time a microphone is turned on, it activates the Mic relay (which delivers
audio to the summing bus), illuminates the ‘channel on’ LED, and, if the mute jumper is
installed, activates the mute relay. The telephone-channel relay also provides the
contact closure to ground at the remote connector.
In addition, there are ‘start’ and ‘stop’ pulses ( to ground through open collectors)
available for both the telephone and computer channels. These pulses are
approximately 100ms in duration. Pulse duration is determined by the 6.8 ufd capacitor
and the 100k resistor. Tally lights for the talkback switches are simple ground starts.