Metering
The NM-250 MKII uses the LM3916N-1 monolithic integrated circuit to provide an
electronic version of the VU meter. The metering circuitry is on both the main PC board
and the PC board which mounts behind the front panel.
As seen in the schematic below, a 5532 is employed as buffers between the main
output amplifiers and the metering circuitry. Drive for the meters is controlled by the two
trim-pots located on the main PC board. The second 5532 op-amp is configured as
precision half-wave rectifiers. The timing of this circuit provides an average reading
meter.
When shipped, the unit is set so that 0 VU = +4 dBm.